Description


One component industrial glue based on modified poly vinyl acetate. Water resistance D2.

Usage

Usage

FIELDS OF APPLICATION

UMACOLL 21D is suitable for all types of solid wood, HDF, chipboards, flat lamination and veneer of moisture exposed surfaces. Water resistance D2 (DIN EN204:1991). Suitable for hot and cold pressing.

Suitable for: 

  • Door production
  • Tongue and groove joints
  • Finger joints without condensate and water impact
  • Gluing of composite boards (plywood)
  • Furniture
  • Flat lamination and veneer

SUBSTRATE

Not lower than +10°С is recommended for gluing process.  After drying forms stable flexible transparent adhesive line. Short open time. Non toxic, non inflammable. Non frost proof. Neutral pH! Goods are intended to be used inside with possible short-term exposure to water or condensation and/or short-term high humidity with wood humidity increasing up to 18%.

Technical information

Technical information

Form

White or yellowish viscous liquid without lumps and impurities, surface film is acceptable

Polymer

Modified poly vinyl acetate

Mass fraction of dry residue

Not below 50%

VMC (20+2)оС

11-100***

Adhesive Bond

Not below 400 N/m

рН-value

4,0-6,0

Water proof class

D2/EN 204

Consumption

100 /// 200 g/m²

Open assembly time at +20°С

Max 8 min

Pressing time at +20°С

Max 10 min

Pressure for unstressed work piece

0,1 … 1,0 МPа

Room, material and adhesive temperature

(20+2)°С

Wood humidity

8 - 12%

Relative air humidity

65%

Bond thermal stability acc. to WATT 91 at 80°С

≥ 7,5 N/mm2

***More definite viscosity is available to customers need

CERTIFICATE

The product «Poly vinyl acetate homopolymer poor-dispersion» isn’t included in Part II of «Consolidated list of goods, subjected to Sanitary and Epidemiological Control at the Custom and the Customs Union Territory», proved by Commission of the Customs Union, on the 28th of May, 2010, №299, and not under mandatory certification.⁠

Application

Application

INSTRUCTION FOR USE

The surfaces of gluing materials should be dust free and seasoned to room temperature.

CONDITIONS

Working temperature (20+2)°С and air humidity not below 65%. Use at the temperature not below10°С only.

WORKING CONDITIONS

Preparing

Ready to use. No thinning needed. Stir thoroughly before use!

Remove surface film carefully if any. The final joint strength and water resistance   are achieved in 7 days in rooms with possible short-term exposure to water or condensation and/or short-term high humidity.

Tools

Spatula, brushes, roll, glue application machine, glue roller.

Cleaning

Equipment and tools should be washed after using. Use acetone to cure dry glue. 

Application

Apply the adhesive as a uniform coat on one side.

MATERIAL HUMIDITY

Wood humidity should be 8 - 12%.Wood humidity strongly affects the adhesive bond quality.

HARDENING TIME

Open assembling time no more than 8 min at +20°C, air humidity 65% and consumption 150 g/m2. Joint assembling time: max. 10 min at +20°C. Pressure should be applied before drying. Joint pressure increases if more glue used, at low working temperature and high humidity.

Note that the open assembly time and the required pressing time strongly depend on the working conditions such as room temperature, wood moisture and quality, absorbency and tensions in the material as well as the adhesive amount applied. Our recommendations can therefore only be used as guidance.

Storage

Storage

STORAGE

Store in a dry and cool place at +5…+35 °C, in a tightly sealed original container. Protect from freezing!

GUARANTED STORAGE LIFE

Expire date is 6 months in case if delivery and storing rules are followed. After expire date shouldn’t be used without tests.

HEALTH AND SAFETY

Air the room while working. Avoid skin and eye contact. Use rubber gloves. If skin contact wash with large amount of water. If eye contact wash immediately and consult a doctor. Keep out of reach of children. A separate material safety data sheet is available by request.

RECYCLING

Packing materials are recycled as consumer waste.


#
Write to us
personal data
To request a price
personal data
Order
personal data